Binder co2 incubator service manual




















The actual values of temperature, CO chamber with O control and humidity chamber with active humidification are given at adjustable intervals. Page The maximum head load must not exceed a capacity of 20 W. Damage to the cultures. Heat emission of electrical devices connected inside the CO incubator may modify the temperature range. Measurement data are recorded in the Data Logger and can be read out after the measurement via the RS interface of the Data Logger. It is suitable to connect two electrical devices, one inside and one outside the incubator.

The mounting instructions delivered with the stacking adapter describe its installation Art. The mounting instructions delivered with the base on castors describe its installation Art. Page Measuring Co All the necessary equipment must be supplied by one manufacturer only and in a defined test system. Note: These test systems are not very accurate.

Page Avoiding Microbial Contamination Avoiding microbial contamination The main types of microbial contaminants in cell and tissue culture are bacteria, fungi, yeast, mycoplasma, and viruses.

This chapter gives an overview of potential sources of contamination and precautions and measures to eliminate them. Other products are not approved, since they could in particular damage the sensor. Eye damage due to chemical burns. Following frequent use of the disinfectant spray and prior to hot-air sterilization, remove any agent remainder by using the neutral cleaning agent and then a moistened towel to avoid formation of permanent residues.

Page Preparation For A Hot-Air Sterilization Note: in the case when two chambers are directly stacked on top of each other without using the original BINDER stacking stand or the BINDER stacking adapter, the exact maintenance of the incubation set parameters in one of the chambers while carrying out sterilization in the other one cannot be assured.

Page Prematurely Terminating The Sterilization Cycle Opening the outer door leads to prematurely terminating the running sterilization cycle. If this happens during the heating up or holding phase during 4 hours after starting the sterilization cycle , sterilization will be ineffective chap. Interruption of the temperature reaction time.

The interior may still be hot. Do not touch the glass door and inner surfaces! Confirm the message with the Confirm icon. After confirming the message the controller changes to Fixed value operation mode. The setpoints of Fixed value operation mode are then equilibrated. Page Maintenance And Service Replace the door gasket only when cold. Otherwise, the door gasket may become damaged. We recommend taking out a maintenance agreement. When using gases with less pureness, the changing intervals should be shorter.

An authorization number will be issued after receiving your complaint either in writing or by telephone prior to your sending the BINDER product back to us. Page Disposal Disposal They must not be disposed of at public collecting points. The devices must be free from toxic, infectious or radioactive substances in order to eliminate any health hazards to the employees of the recycling companies. Check connection to power supply. Check power supply for voltage of Wrong voltage. Pressure sensor system Acknowledge the alarm on the defective.

Acknowledge the alarm on the cylinder is not connected controller. Correctly connect the gas correctly. Connected gas cylinder is Acknowledge the alarm on the closed. Page Gas Concentration Acknowledge the alarm on the sensor defective. Recovery time up to 5 vol. Page The Transfer the cultures to another pH indicator of the cell culture sensor defective. Chamber with O control: control not adjusted. Calibrate and adjust O control.

Page Sterilization Doors not closed properly. Close door properly. Humidity set too high. Reduce humidity chap. Condensation on the doors or Door gaskets defective. Page Controller Main power switch turned off.

Turn on the main power switch. Log in with the required higher Menu functions not available with authorization. They are controlled and calibrated to a DKD-Standard at regular intervals. Page Definition Of Usable Volume Page Chamber size Shelves Number of shelves, regular Number of shelves, max. Page Equipment And Options Extract The user is responsible for any risk arising from using unauthorized accessories.

Regular equipment Page Dimensions Page Contamination Clearance Certificate Contamination clearance certificate Boekel Incubator. Catalog Number. Positioning the CO2 incubator. Where you place the incubator can alter its performance. Ventilation, air flow, room temperature, and direct sunlight can all affect the temperature and humidity functions.

When installing a CO2 incubator, be sure to. Drying ovens. ED series. FD series. FED series. FP series. Vacuum drying ovens. VD series. VDL series. CO2 incubators. CB series. Microbiological incubators. BF series. KB series New York State Agency. Environmental Audit. Guidance Manual. April 14, New York State. Department of Environmental Conservation.

Pollution Prevention Unit. Opening of the rear service lid to achieve the area Setting of the door heating CO 2 -Reference Measurement Measuring of CO 2 indirectly via the pH of the Measuring of CO 2 directly via chemical indicator Measuring of CO 2 directly via a electronic measuring Definition of calibration References for calibration Tolerance of the adjustment Temperature calibration Calibration alignment of the temperature controller Reading out of the actual values Result Calibration CO 2 calibration O 2 calibration Component Board.

Especially the Display controller MB1 inside the red triangle is conspicuous. Machine room with all electronic parts N. B Connection socket for low tension supply option. C CO 2 sensor. F O 2 sensor option. Line Series ED Classic. Line Series FD Avantgarde. Line Series FD Classic. Line Series FP Classic. Line Series M Classic. Time program editor for chamber controller MB2 Version 1.

Thermoelectric cooling technology Will Peltier modules supersede the compressor?